QuietCool QC36DVS Owner's Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
5.4
Turn
-
on Fan
Once your
cooling
pads are wet
you may turn on your QuietCool unit. Now you can begin to feel the QuietCool difference
in temperature. After your QuietCool has run for 5 minutes or so, visually inspect the pads if water is dripping outside the
unit
you have too much water, simply turn the water flow valve to the right ½ turn and inspect water flow in another 5
minutes. If there are dry streaks in the cel deck pads open the
water flow valve handle
½ turn to increase water
chec
k water
flow in another 5 minutes and adjust accordingly. Most QuietCool operations work effectively with valve opened between 1
½ -
2 turns.
This water valve is efficient
it requires minimal turning.
6.0
Daily Operating procedures
6
.1
Turn
-
on
water pu
mp
Turn on water
pump
to unit
let cooling
pads get saturated
then turn on fan for cooling.
Adjust the water flow
Your QuietCool operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned
on at 1 ¼ turns
. You must determine what works best for you and your specific environment.
6.2
Adjust water flow
Your QuietCool operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned
on at 1 ¼ turns. You must determine
what works best for you and your specific environment.
6
.2
Turn on fan
When you can see that the cooling pads are saturated with water
turn on the fan and feel the cooler air coming from your
QuietCool unit. Adjust the fan speed for your comfort.
6.4
Turn
-
off unit
at end of day
15 minutes before closing for the day
turn off water pump with
tog
gle
switch
leave fan running
this action will shut
-
off
water to the cooling pads while keeping the fan running. The fan will dry out the
cooling
pads. When the cooling pads are
thoroughly dry turn off fan. Drying your cooling pads thoroughly - everyday will
help
prevent mold and mildew growth,
plus
it will
prolong the life of your cooling
pads.
7
.0
Maintenance
7
.1
Access inside of unit
Turn
-
off water pu
mp and let the fan continue to run until the cooling
pads are thoroughly dry (about 10
15 minutes). Once
your cooling
pads are completely dry you may turn
-
off fan. Now unplug electricity to unit to avoid unnecessary shock. Next,
using a 7/16” wrench remove the two retaining bolts from the backside and topside (cooling pad side) of the unit. These
two bolts hold the
metal
angle retaining bar and the
cooling
pads in place. Next, remove the angle retaining bar and set to
side. Now you are ready to remove y
our
unit’s
cooling
pads.
7
.2
Removing the cooling
pads
Before your start, make a note of the direction of the angle of the pads flutes
(see side of pads).
You must put pads
back in correct order for your unit to function effectively.
(Note: Install s
teep
side
45°
angle flute to the back
of unit
.)
Page view 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Comments to this Manuals

No comments